Infant Incubator

( 0 reviews )

Infant Incubator is one of the important equipment used in medical institutions. It is mainly used for constant temperature cultivation, temperature resuscitation, oxygen delivery, rescue, hospitalization and observation of sick infants and premature infants. It is used in hospitals, confinement centers, neonatology, etc.

Features:

  • LCD display
  • Double control modes of bed temperature and skin temperature
  • Double-layer thermostatic cover, automatic air curtain device
  • Humidity control function
  • Air & Oxygen blender
  • Oxygen supply system
  • Baby cot is infinitely adjustable
  • 24 kinds of sound and light alarm, comprehensive protection of baby safety

 

General

Parameters

Item

Power supply

Specifications

1320VA; 11 OV 60Hz (Optional)

Size

Maximum heater output power (220VAC)

mm

Air chamber heater: 330W,

Water tank heater: 155W

Auxiliary network power output

Heater indication

AC220V/50Hz,Both maximum permissible currents are 220V I .5A

10% increasing amount

Temperature control mode Bed temperature mode;The skin temperature mode
Bed temperature control temperature range 25.W37.ooc;

37.1 -039.ooc (Span Mode)

Skin temperature control range 34.W37.ooc; 37.W38.ooc (Span Mode)
Skin temperature sensor temperature display range 5.w65.ooc
Heating time s 50min
Temperature variability
Temperature uniformity

(mattress in horizontal position)

0.80C
Humidity Control The running time of the tank after it is filled with distilled water Humidity below 70%RH, at least 24h
Water tank capacity

Humidity display range

1500ml
Humidity control range

Humidity control accuracy

% per adjustment)
Oxygen

Concentration

Control

Oxygen concentration display range 00W99%
Oxygen concentration display resolution 1%
Oxygen concentration control accuracy ±5% oxygen volume concentration
Oxygen concentration setting range 21% — 60% (1% per adjustment)
Oxygen sensor service life The maximum use time is 10000h at 100% oxygen concentration
Transport Storage Temperature -200C&+550C
Atmospheric pressure range 500hPaæ.1060hPa
Relative humidity 93%RH
Packing size/ Gross Weight

Relative humidity

Base packing size:                               50Kg

Body packing size: 1100*710*855mm 60Kg

The Work

Environment

The environment temperature
Pressure range 700hParv1060hPa
Service altitude 9000m
Over voltage category Il
Pollution levels 2
Ambient air velocity s 0.3m/s
Other

Indicators

Environmental noise in incubator baby compartment No more than 55dB(A) at stable temperature
Carbon dioxide concentration in the infant compartment A mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL/min to a point 1 Ocm above the mattress center and IOcm above the center. The concentration was less than 0.5% after stabilization
The velocity of air flow over a baby’s mattress ‘0.35m/s
General

Alarm

Power off alarm,Fan alarm, sensor alarm, Deviation alarm, Over temperature alarm, Water tank placement error alarm, Water shortage alarm
The System

Alarm

Mcul and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, Analog-to-digital conversion chip 2544 fault alarm, Analog-to-digital conversion chip 2548 fault alarm, Over temperature alarm, Temperature heating system fault, Humidity heating system fault
Model

Temp. Control

Type l,

Bed/Skin temperature

Type I l

Bed/Skin temperature

Display LCD LCD
Bed Temp. Control Range 250C-390C 250C-390C
Skin Temp. Control Range Humidity Control Range 340C-380C
Oxygen Control Range
Cabinet Yes Yes

 